DIESEL INJECTION
Fault finding – Test13B
13B -254V3 MR-372-J84-13B250$900.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
TEST6
CONTINUED 2
Checking the turbocharging pressure regulator for a turbocharger with variable geometry
Note:
The rod of the pressure regulator on a turbocharger with variable geometry is perpendicular to the turbocharger
shaft.
Turbochargers with variable geometry are controlled by a solenoid valve.
According to the vehicle type, maximum visual access will either be from above or from below.
Note:
If necessary, according to the vehicle type and the accessibility of the pressure regulator, connect the vacuum
pump to the end of the pressure regulator pipe at the solenoid valve outlet.
Using a manual vacuum pump, apply a vacuum on the turbocharging pressure regulator of approximately
650 mbar.
1- Check that the fitting is completely sealed.
2- Check that the control rod is resting against its stop.
3- Lock the vacuum device and check that the pressure variation is not greater than 100 mbar in 10 seconds.
4- Release the pressure and check that the control rod returns to its initial position without jerking.
Repeat the entire sequence three times.
Is the pressure regulator sealing and rod movement correct?
YES NO
The turbocharger is correct.
End of procedure.Replace the turbocharger (see MR 364 (Mégane II)
or 370 (Scénic II), Mechanical, 12B,
Turbocharging, Turbocharger: Removal -
Refitting and Technical Note 3938A, Broken
turbocharger: Replacement instructions).

Page 255 of 273

DIESEL INJECTION
Fault finding – Test13B
13B -255V3 MR-372-J84-13B250$900.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
TEST6
CONTINUED 3
Checking the turbocharging pressure regulator for a turbocharger with fixed geometry
Note:
The pressure regulator rod for a turbocharger with fixed geometry is line with the turbocharger shaft.
Turbochargers with fixed, regulated geometry are controlled by a solenoid valve.
According to the vehicle type, maximum visual access will either be from above or from below.
Note:
If necessary, according to the vehicle type and the accessibility of the pressure regulator, connect the vacuum
pump to the end of the pressure regulator pipe at the solenoid valve outlet.
Using a manual vacuum pump, apply a vacuum on the turbocharging pressure regulator of approximately
650 mbar.
1- Check that the fitting is correctly sealed.
2- Check that the control rod moved several millimetres.
3- Lock the vacuum device and check that the pressure variation is not greater than 100 mbar over 10 seconds.
4- Release the pressure and check that the control rod returns to its initial position without jerking.
Repeat the entire sequence three times.
Is the pressure regulator sealing and rod movement correct?
YES NO
The turbocharger is correct.
End of procedure.Replace the turbocharger (see MR 364 (Mégane II)
or 370 (Scénic II), Mechanical, 12B,
Turbocharging, Turbocharger: Removal -
Refitting and Technical Note 3938A, Broken
turbocharger: Replacement instructions).